Page 8 of 15
Electric Motor Armature
This photograph shows an electric motor armature reclaimed on the journal area. The work was carried out using a Metallisation Arc Spray Unit and a deposit of 2.54mm (0.100”) of S2 was applied. The repair was completed in approximately 36 hours as opposed to a delivery period of several months for a new unit. The cost of reclamation was about 1% of the cost of replacement.